<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Power Solutions &#8211; Mecer</title>
	<atom:link href="https://mecer.co.za/category/products/power-solutions/feed/" rel="self" type="application/rss+xml" />
	<link>https://mecer.co.za</link>
	<description>Made for Progress: Empowering South Africans Through Technology</description>
	<lastBuildDate>Wed, 07 May 2025 08:06:40 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://mecer.co.za/wp-content/uploads/2023/05/mecer.png</url>
	<title>Power Solutions &#8211; Mecer</title>
	<link>https://mecer.co.za</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Offline Range VUVU+ &#8211; ME-650-VU-1</title>
		<link>https://mecer.co.za/offline-range-vuvu-me-650-vu-1/</link>
					<comments>https://mecer.co.za/offline-range-vuvu-me-650-vu-1/#respond</comments>
		
		<dc:creator><![CDATA[Mecer]]></dc:creator>
		<pubDate>Mon, 05 May 2025 08:18:00 +0000</pubDate>
				<category><![CDATA[Power Solutions]]></category>
		<category><![CDATA[Products]]></category>
		<guid isPermaLink="false">https://mecer.chronon.co.za/?p=9491</guid>

					<description><![CDATA[MODEL ME-650-VU ME-850-VU ME-1000-VU ME-2000-VU CAPACITY 600 VA / 360 W 800VA / 480 W 1000 VA / 600 W 2000 VA / 1200 W INPUT Voltage 110/120 VAC or 220/230/240 VAC Voltage Range 81-145 VAC / 162-290 VAC Frequency Range 60/50 Hz (auto sensing) OUTPUT AC Voltage Regulation (Batt. Mode) ±10% Frequency Range (Batt. [&#8230;]]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="9491" class="elementor elementor-9491">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-22d8f84b elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="22d8f84b" data-element_type="section" data-e-type="section" data-settings="{&quot;jet_parallax_layout_list&quot;:[]}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1168f9e" data-id="1168f9e" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-114b2084 elementor-widget elementor-widget-text-editor" data-id="114b2084" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<table border="1">
  <tr>
    <th>MODEL</th>
    <th>ME-650-VU</th>
    <th>ME-850-VU</th>
    <th>ME-1000-VU</th>
    <th>ME-2000-VU</th>
  </tr>
  <tr>
    <td>CAPACITY</td>
    <td>600 VA / 360 W</td>
    <td>800VA / 480 W</td>
    <td>1000 VA / 600 W</td>
    <td>2000 VA / 1200 W</td>
  </tr>
  <tr>
    <td colspan="5"><strong>INPUT</strong></td>
  </tr>
  <tr>
    <td>Voltage</td>
    <td colspan="4">110/120 VAC or 220/230/240 VAC</td>
  </tr>
  <tr>
    <td>Voltage Range</td>
    <td colspan="4">81-145 VAC / 162-290 VAC</td>
  </tr>
  <tr>
    <td>Frequency Range</td>
    <td colspan="4">60/50 Hz (auto sensing)</td>
  </tr>
  <tr>
    <td colspan="5"><strong>OUTPUT</strong></td>
  </tr>
  <tr>
    <td>AC Voltage Regulation (Batt. Mode)</td>
    <td colspan="4">±10%</td>
  </tr>
  <tr>
    <td>Frequency Range (Batt. Mode)</td>
    <td colspan="4">60 Hz or 50 Hz ±1 Hz</td>
  </tr>
  <tr>
    <td>Transfer Time</td>
    <td colspan="4">Typical 2-6 ms, 10ms max.</td>
  </tr>
  <tr>
    <td>Waveform (Batt. Mode)</td>
    <td colspan="4">Simulated Sine Wave</td>
  </tr>
  <tr>
    <td colspan="5"><strong>BATTERY</strong></td>
  </tr>
  <tr>
    <td>Battery Type &#038; Number</td>
    <td>12 V/7 AH x 1</td>
    <td>12 V/7 AH x 1</td>
    <td>12 V/7 AH x 2</td>
    <td>12 V/7 AH x 2</td>
  </tr>
  <tr>
    <td>Typical Recharge Time</td>
    <td colspan="4">4-6 hours recover to 90% capacity</td>
  </tr>
  <tr>
    <td colspan="5"><strong>PHYSICAL</strong></td>
  </tr>
  <tr>
    <td>Dimension, D X W X H(mm)</td>
    <td colspan="2">287 x 100 x 142</td>
    <td>350 x 146 x 160</td>
    <td>397 x 146 x 205</td>
  </tr>
  <tr>
    <td>Net Weight (kgs)</td>
    <td>4.25</td>
    <td>4.9</td>
    <td>8</td>
    <td>11.5</td>
  </tr>
</table>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
					<wfw:commentRss>https://mecer.co.za/offline-range-vuvu-me-650-vu-1/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>IVR-MPPT Range</title>
		<link>https://mecer.co.za/ivr-mppt-range/</link>
					<comments>https://mecer.co.za/ivr-mppt-range/#respond</comments>
		
		<dc:creator><![CDATA[Mecer]]></dc:creator>
		<pubDate>Mon, 05 May 2025 08:11:33 +0000</pubDate>
				<category><![CDATA[Power Solutions]]></category>
		<category><![CDATA[Products]]></category>
		<guid isPermaLink="false">https://mecer.chronon.co.za/?p=9484</guid>

					<description><![CDATA[IVR-1200MPPT/ IVR-2400MPPT • Simulated sinewave inverter • Wide input voltage range • 12VDC or 24VDC available • Overload and short circuit protection • LCD display for comprehensive information • MPPT &#60;table&#62;&#60;tr&#62;&#60;th&#62;MODEL&#60;/th&#62;&#60;td&#62;IVR-1200MPPT&#60;/td&#62;&#60;td&#62;IVR-2400MPPT&#60;/td&#62;&#60;/tr&#62;&#60;tr&#62;&#60;th&#62;CAPACITY&#60;/th&#62;&#60;td&#62;1200VA/1000W&#60;/td&#62;&#60;td&#62;2400VA/1800W&#60;/td&#62;&#60;/tr&#62;&#60;tr&#62;&#60;th&#62;POWER FACTOR&#60;/th&#62;&#60;td&#62;0.83&#60;/td&#62;&#60;td&#62;0.75&#60;/td&#62;&#60;/tr&#62;&#60;tr&#62;&#60;th colspan=&#8221;3&#8243;&#62;INPUT&#60;/th&#62;&#60;/tr&#62;&#60;tr&#62;&#60;th&#62;Voltage&#60;/th&#62;&#60;td colspan=&#8221;2&#8243;&#62;220-240 VAC&#60;/td&#62;&#60;/tr&#62;&#60;tr&#62;&#60;th&#62;Voltage Range&#60;/th&#62;&#60;td colspan=&#8221;2&#8243;&#62;90-280 VAC&#60;/td&#62;&#60;/tr&#62;&#60;tr&#62;&#60;th&#62;Nominal Operating Frequency&#60;/th&#62;&#60;td colspan=&#8221;2&#8243;&#62;50/60Hz&#60;/td&#62;&#60;/tr&#62;&#60;tr&#62;&#60;th&#62;Maximum Input Current&#60;/th&#62;&#60;td&#62;10A&#60;/td&#62;&#60;td&#62;13A&#60;/td&#62;&#60;/tr&#62;&#60;tr&#62;&#60;th colspan=&#8221;3&#8243;&#62;OUTPUT&#60;/th&#62;&#60;/tr&#62;&#60;tr&#62;&#60;th&#62;Nominal Output Voltage&#60;/th&#62;&#60;td colspan=&#8221;2&#8243;&#62;220-240 VAC&#60;/td&#62;&#60;/tr&#62;&#60;tr&#62;&#60;th&#62;Voltage Regulation (Batt. Mode)&#60;/th&#62;&#60;td colspan=&#8221;2&#8243;&#62;+/-10%&#60;/td&#62;&#60;/tr&#62;&#60;tr&#62;&#60;th&#62;Output Frequency Range&#60;/th&#62;&#60;td colspan=&#8221;2&#8243;&#62;50/60Hz&#60;/td&#62;&#60;/tr&#62;&#60;tr&#62;&#60;th&#62;Nominal [&#8230;]]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="9484" class="elementor elementor-9484">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-22d8f84b elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="22d8f84b" data-element_type="section" data-e-type="section" data-settings="{&quot;jet_parallax_layout_list&quot;:[]}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1168f9e" data-id="1168f9e" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-822a47b elementor-widget elementor-widget-text-editor" data-id="822a47b" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<table width="233"><tbody><tr><td width="233">IVR-1200MPPT/ IVR-2400MPPT</td></tr><tr><td>• Simulated sinewave inverter</td></tr><tr><td>• Wide input voltage range</td></tr><tr><td>• 12VDC or 24VDC available</td></tr><tr><td>• Overload and short circuit protection</td></tr><tr><td>• LCD display for comprehensive information</td></tr><tr><td>• MPPT</td></tr></tbody></table>								</div>
				</div>
				<div class="elementor-element elementor-element-114b2084 elementor-widget elementor-widget-text-editor" data-id="114b2084" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>&lt;table&gt;<br />&lt;tr&gt;<br />&lt;th&gt;MODEL&lt;/th&gt;<br />&lt;td&gt;IVR-1200MPPT&lt;/td&gt;<br />&lt;td&gt;IVR-2400MPPT&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;CAPACITY&lt;/th&gt;<br />&lt;td&gt;1200VA/1000W&lt;/td&gt;<br />&lt;td&gt;2400VA/1800W&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;POWER FACTOR&lt;/th&gt;<br />&lt;td&gt;0.83&lt;/td&gt;<br />&lt;td&gt;0.75&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th colspan=&#8221;3&#8243;&gt;INPUT&lt;/th&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Voltage&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;220-240 VAC&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Voltage Range&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;90-280 VAC&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Nominal Operating Frequency&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;50/60Hz&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Maximum Input Current&lt;/th&gt;<br />&lt;td&gt;10A&lt;/td&gt;<br />&lt;td&gt;13A&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th colspan=&#8221;3&#8243;&gt;OUTPUT&lt;/th&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Nominal Output Voltage&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;220-240 VAC&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Voltage Regulation (Batt. Mode)&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;+/-10%&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Output Frequency Range&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;50/60Hz&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Nominal Output Current&lt;/th&gt;<br />&lt;td&gt;5.2A&lt;/td&gt;<br />&lt;td&gt;10.4A&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Inrush Current&lt;/th&gt;<br />&lt;td&gt;10A&lt;/td&gt;<br />&lt;td&gt;13A&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Maximum Output Fault Current&lt;/th&gt;<br />&lt;td&gt;6.9A&lt;/td&gt;<br />&lt;td&gt;13.6A&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Transfer Time&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;20 ms typical&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Waveform&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;Simulated Sine Wave&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th colspan=&#8221;3&#8243;&gt;BATTERY&lt;/th&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Battery Voltage&lt;/th&gt;<br />&lt;td&gt;12 VDC&lt;/td&gt;<br />&lt;td&gt;24 VDC&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Maximum Battery Discharging Current&lt;/th&gt;<br />&lt;td&gt;100A&lt;/td&gt;<br />&lt;td&gt;90A&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Floating Charge Voltage&lt;/th&gt;<br />&lt;td&gt;13.7 VDC ±0.5 VDC&lt;/td&gt;<br />&lt;td&gt;27.4 VDC ±1 VDC&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th rowspan=&#8221;2&#8243;&gt;CV Charging Voltage&lt;/th&gt;<br />&lt;th&gt;Lead Acid Battery&lt;/th&gt;<br />&lt;td&gt;14.3 VDC ±0.5 VDC&lt;/td&gt;<br />&lt;td&gt;28.6 VDC ±1 VDC&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Lithium Battery&lt;/th&gt;<br />&lt;td&gt;14.6 VDC ±0.5 VDC&lt;/td&gt;<br />&lt;td&gt;29.2 VDC ±1 VDC&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Cut Off Voltage&lt;/th&gt;<br />&lt;td&gt;10.5 VDC ±0.5 VDC&lt;/td&gt;<br />&lt;td&gt;21.0 VDC ±1 VDC&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Maximum AC Charging Current&lt;/th&gt;<br />&lt;td&gt;10 A or 25 A&lt;/td&gt;<br />&lt;td&gt;10 A or 25 A&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th colspan=&#8221;3&#8243;&gt;SOLAR CHARGER&lt;/th&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Solar Charger Type&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;MPPT&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Maximum PV Array Open Circuit Voltage&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;100 VDC&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;MPP Range @ Operating Voltage&lt;/th&gt;<br />&lt;td&gt;15 ~ 80 VDC&lt;/td&gt;<br />&lt;td&gt;30 ~ 80 VDC&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Max. PV array Input Power&lt;/th&gt;<br />&lt;td&gt;825W&lt;/td&gt;<br />&lt;td&gt;1650W&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Max. PV array Power to support&lt;/th&gt;<br />&lt;td&gt;660W&lt;/td&gt;<br />&lt;td&gt;1320W&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Maximum Solar Charging Current&lt;/th&gt;<br />&lt;td&gt;55 A&lt;/td&gt;<br />&lt;td&gt;55 A&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Maximum Charging Current (Utility +SCC)&lt;/th&gt;<br />&lt;td&gt;55 A&lt;/td&gt;<br />&lt;td&gt;55 A&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th colspan=&#8221;3&#8243;&gt;PHYSICAL&lt;/th&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Dimension (DxWxH) mm&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;272 x 212 x 127&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Net Weight (kgs)&lt;/th&gt;<br />&lt;td&gt;4.5&lt;/td&gt;<br />&lt;td&gt;4.8&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Protective Class&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;I&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Ingress Protection Rating&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;IP20&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th colspan=&#8221;3&#8243;&gt;ENVIRONMENT&lt;/th&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Humidity&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;0 ~ 90% RH (No condensing)&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Operating Temperature&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;0 ~ 55°C&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;tr&gt;<br />&lt;th&gt;Altitude&lt;/th&gt;<br />&lt;td colspan=&#8221;2&#8243;&gt;0 ~ 1000 m&lt;/td&gt;<br />&lt;/tr&gt;<br />&lt;/table&gt;</p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
					<wfw:commentRss>https://mecer.co.za/ivr-mppt-range/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>ME-3000-PEB</title>
		<link>https://mecer.co.za/me-3000-peb/</link>
					<comments>https://mecer.co.za/me-3000-peb/#respond</comments>
		
		<dc:creator><![CDATA[Mecer]]></dc:creator>
		<pubDate>Mon, 05 May 2025 08:09:43 +0000</pubDate>
				<category><![CDATA[Power Solutions]]></category>
		<category><![CDATA[Products]]></category>
		<guid isPermaLink="false">https://mecer.chronon.co.za/?p=9478</guid>

					<description><![CDATA[Mecer 3000VA / 3000W Portable Energy Bank LiFPO4 2.5KWh Built-in &#8211; White with AVR, monitor software + cable &#38; Built-in Surge protector, MPPT]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="9478" class="elementor elementor-9478">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-22d8f84b elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="22d8f84b" data-element_type="section" data-e-type="section" data-settings="{&quot;jet_parallax_layout_list&quot;:[]}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1168f9e" data-id="1168f9e" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-822a47b elementor-widget elementor-widget-text-editor" data-id="822a47b" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<table width="349"><tbody><tr><td width="349">Mecer 3000VA / 3000W Portable Energy Bank</td></tr><tr><td>LiFPO4 2.5KWh Built-in &#8211; White</td></tr><tr><td>with AVR, monitor software + cable &amp; Built-in Surge protector, MPPT</td></tr></tbody></table>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
					<wfw:commentRss>https://mecer.co.za/me-3000-peb/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Online Rack Mount Range WPRU/WPRV</title>
		<link>https://mecer.co.za/online-rack-mount-range-wpru-wprv/</link>
					<comments>https://mecer.co.za/online-rack-mount-range-wpru-wprv/#respond</comments>
		
		<dc:creator><![CDATA[Mecer]]></dc:creator>
		<pubDate>Mon, 05 May 2025 08:06:41 +0000</pubDate>
				<category><![CDATA[Power Solutions]]></category>
		<category><![CDATA[Products]]></category>
		<guid isPermaLink="false">https://mecer.chronon.co.za/?p=9472</guid>

					<description><![CDATA[Maximize uptime and peace of mind with our Online UPS’s that keep your systems running smoothly]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="9472" class="elementor elementor-9472">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-22d8f84b elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="22d8f84b" data-element_type="section" data-e-type="section" data-settings="{&quot;jet_parallax_layout_list&quot;:[]}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1168f9e" data-id="1168f9e" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-822a47b elementor-widget elementor-widget-text-editor" data-id="822a47b" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<table width="259"><tbody><tr><td width="259">Maximize uptime and peace of mind with our Online UPS&#8217;s that keep your systems running smoothly.</td></tr><tr><td> </td></tr><tr><td>E-1000-WPRU/ME-2000-WPRU/ME-3000-WPRU &#8211; ME-6000-WPRU/ME-10000-WPRU</td></tr><tr><td>• True double-conversion online UPS</td></tr><tr><td>• Wide input voltage range (110-300 VAC)</td></tr><tr><td>• Input power factor correction 0.99</td></tr><tr><td>• Output power factor 0.8</td></tr><tr><td>• Converter mode available</td></tr><tr><td>• ECO mode operation for energy saving (only available for 1-3KVA)</td></tr><tr><td>• Hot-swappable battery design only available for 1-3KVA</td></tr><tr><td>• Generator compatible</td></tr><tr><td>• Adjustable charging current via LCD or software (1A ~ 6A)</td></tr><tr><td>• Emergency power off function only available for 6K and up models</td></tr></tbody></table>								</div>
				</div>
				<div class="elementor-element elementor-element-114b2084 elementor-widget elementor-widget-text-editor" data-id="114b2084" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<table border="1" cellpadding="5">
  <tr>
    <th>MODEL</th>
    <th>ME-1000-WPRU</th>
    <th>ME-2000-WPRU</th>
    <th>ME-3000-WPRU</th>
    <th>ME-6000-WPRU</th>
    <th>ME-10000-WPRU</th>
  </tr>
  <tr>
    <td>PHASE</td>
    <td colspan="5">Single phase with ground</td>
  </tr>
  <tr>
    <td>CAPACITY</td>
    <td>1000 VA / 800 W</td>
    <td>2000 VA / 1600 W</td>
    <td>3000 VA / 2400 W</td>
    <td>6000 VA / 4800 W</td>
    <td>10000 VA / 8000 VA</td>
  </tr>
  <tr>
    <td colspan="6"><strong>INPUT</strong></td>
  </tr>
  <tr>
    <td rowspan="4">Voltage Range</td>
    <td colspan="3">160 VAC/140 VAC/120 VAC/110 VAC ± 5% (Ambient Temp.<35°C)<br>(based on load percentage 100% &#8211; 80 % / 80 % &#8211; 70 % / 70 &#8211; 60 % / 60 % &#8211; 0)</td>
    <td colspan="2">176 VAC ± 3% @ 100% load<br>110 VAC ± 3% @ 50% load</td>
  </tr>
  <tr>
    <td colspan="3">175 VAC /155 VAC/ 135 VAC /125 VAC± 5 % (Ambient Temp.<35°C)<br>(based on load percentage 100% &#8211; 80 % / 80 % &#8211; 70 % / 70 &#8211; 60 % / 60 % &#8211; 0)</td>
    <td colspan="2">186 VAC ± 3% @ 100% load<br>120 VAC ± 3% @ 50% load</td>
  </tr>
  <tr>
    <td colspan="3">300 VAC ± 5 %</td>
    <td colspan="2">300 VAC ± 3%</td>
  </tr>
  <tr>
    <td colspan="3">290 VAC ± 5 %</td>
    <td colspan="2">290 VAC ± 3%</td>
  </tr>
  <tr>
    <td>Frequency Range</td>
    <td colspan="3">40Hz ~ 70 Hz</td>
    <td colspan="2">46~54 Hz or 56~64 Hz</td>
  </tr>
  <tr>
    <td>Power Factor</td>
    <td colspan="3">≧ 0.99 @ nominal voltage</td>
    <td colspan="2">≧ 0.99 @ 100%load</td>
  </tr>
  <tr>
    <td colspan="6"><strong>OUTPUT</strong></td>
  </tr>
  <tr>
    <td>Output Voltage</td>
    <td colspan="3">200/208/220/230/240 VAC</td>
    <td colspan="2">208/220/230/240 VAC</td>
  </tr>
  <tr>
    <td>AC Voltage Regulation (Batt. Mode)</td>
    <td colspan="5">± 1%</td>
  </tr>
  <tr>
    <td>Frequency Range (Synchronized Range)</td>
    <td colspan="3">47 ~ 53 Hz or 57 ~ 63 Hz</td>
    <td colspan="2">46~54 Hz or 56~64 Hz</td>
  </tr>
  <tr>
    <td>Frequency Range (Batt. Mode)</td>
    <td colspan="3">50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz</td>
    <td colspan="2">50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz</td>
  </tr>
  <tr>
    <td>Current Crest Ratio</td>
    <td colspan="5">3:1</td>
  </tr>
  <tr>
    <td>Harmonic Distortion</td>
    <td colspan="3">≦ 3 % THD (Linear Load)<br>≦ 6% THD (non-linear load)</td>
    <td colspan="2">≦ 3 % THD (Linear Load)<br>≦ 5 % THD (Non-linear Load)</td>
  </tr>
  <tr>
    <td rowspan="2">Transfer Time</td>
    <td colspan="5">Zero</td>
  </tr>
  <tr>
    <td colspan="3">4 ms (Typical)</td>
    <td colspan="2">Zero</td>
  </tr>
  <tr>
    <td>Waveform (Batt. Mode)</td>
    <td colspan="5">Pure Sinewave</td>
  </tr>
  <tr>
    <td colspan="6"><strong>EFFICIENCY</strong></td>
  </tr>
  <tr>
    <td>AC Mode</td>
    <td>88%</td>
    <td>89%</td>
    <td>90%</td>
    <td>92%</td>
    <td>93%</td>
  </tr>
  <tr>
    <td>Battery Mode</td>
    <td>83%</td>
    <td>87%</td>
    <td>88%</td>
    <td>90%</td>
    <td>91%</td>
  </tr>
  <tr>
    <td colspan="6"><strong>BATTERY</strong></td>
  </tr>
  <tr>
    <td>Battery Type</td>
    <td>12 V / 9Ah</td>
    <td>12 V / 9Ah</td>
    <td>12 V / 9Ah</td>
    <td>12 V / 9 Ah</td>
    <td>12 V / 9 Ah</td>
  </tr>
  <tr>
    <td>Numbers</td>
    <td>2</td>
    <td>4</td>
    <td>6</td>
    <td>16</td>
    <td>16</td>
  </tr>
  <tr>
    <td>Typical Recharge Time</td>
    <td colspan="3">4 hours recover to 90% capacity</td>
    <td colspan="2">9 hours recover to 90% capacity</td>
  </tr>
  <tr>
    <td>Charging Current (max.)</td>
    <td colspan="3">1.0 A</td>
    <td colspan="2">1.0 A / 2.0 A (adjustable)</td>
  </tr>
  <tr>
    <td>Charging Voltage</td>
    <td>27.4 VDC ± 1%</td>
    <td>54.7 VDC ± 1%</td>
    <td>82.1 VDC ±1%</td>
    <td>218.4 VDC ±1%</td>
    <td>218.4 VDC ±1%</td>
  </tr>
</table>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
					<wfw:commentRss>https://mecer.co.za/online-rack-mount-range-wpru-wprv/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Online Tower Range WPTU+/WPTV</title>
		<link>https://mecer.co.za/online-tower-range-wptu-wptv/</link>
					<comments>https://mecer.co.za/online-tower-range-wptu-wptv/#respond</comments>
		
		<dc:creator><![CDATA[Mecer]]></dc:creator>
		<pubDate>Mon, 05 May 2025 07:59:23 +0000</pubDate>
				<category><![CDATA[Power Solutions]]></category>
		<category><![CDATA[Products]]></category>
		<guid isPermaLink="false">https://mecer.chronon.co.za/?p=9458</guid>

					<description><![CDATA[When precision and reliability matter most, our Online UPS delivers unmatched performance]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="9458" class="elementor elementor-9458">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-22d8f84b elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="22d8f84b" data-element_type="section" data-e-type="section" data-settings="{&quot;jet_parallax_layout_list&quot;:[]}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1168f9e" data-id="1168f9e" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-822a47b elementor-widget elementor-widget-text-editor" data-id="822a47b" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<table width="233"><tbody><tr><td width="233">When precision and reliability matter most, our Online UPS delivers unmatched performance.</td></tr><tr><td> </td></tr><tr><td>ME-1000-WPTU/ME-2000-WPTU/ME-3000-WPTU/ME-6000-WPTU/ME-10000-WPTU</td></tr><tr><td>• True double-conversion online UPS</td></tr><tr><td>• Wide input voltage range (110-300 VAC)</td></tr><tr><td>• Input power factor correction 0.99</td></tr><tr><td>• Output power factor 0.8</td></tr><tr><td>• Converter mode available</td></tr><tr><td>• ECO mode operation for energy saving (only available for 1-3KVA)</td></tr><tr><td>• Generator compatible</td></tr><tr><td>• Adjustable battery numbers only available for 6K and up models</td></tr><tr><td>• Smart SNMP works well with either USB or RS-232 together</td></tr><tr><td>• Emergency power off function only available for 6K and up models</td></tr></tbody></table>								</div>
				</div>
				<div class="elementor-element elementor-element-114b2084 elementor-widget elementor-widget-text-editor" data-id="114b2084" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<table border="1" cellpadding="5" cellspacing="0">
  <tr>
    <th>MODEL</th>
    <th>ME-1000-WPTU</th>
    <th>ME-2000-WPTU</th>
    <th>ME-3000-WPTU</th>
    <th>ME-6000-WPTU</th>
    <th>ME-10000-WPTU</th>
  </tr>
  <tr>
    <td>PHASE</td>
    <td colspan="5">Single phase with ground</td>
  </tr>
  <tr>
    <td>CAPACITY</td>
    <td>1000 VA / 800 W</td>
    <td>2000 VA / 1600 W</td>
    <td>3000 VA / 2400 W</td>
    <td>6000 VA / 4800 W</td>
    <td>10000 VA / 8000 VA</td>
  </tr>
  <tr>
    <td colspan="6"><strong>INPUT</strong></td>
  </tr>
  <tr>
    <td rowspan="4">Voltage Range</td>
    <td colspan="3">160 VAC/140 VAC/120 VAC/110 VAC ± 5% (Ambient Temp.<35°C)<br>(based on load percentage 100% &#8211; 80 % / 80 % &#8211; 70 % / 70 &#8211; 60 % / 60 % &#8211; 0)</td>
    <td colspan="2">176 VAC ± 3% @ 100% load<br>110 VAC ± 3% @ 50% load</td>
  </tr>
  <tr>
    <td colspan="3">175 VAC /155 VAC/ 135 VAC /125 VAC± 5 % (Ambient Temp.<35°C)<br>(based on load percentage 100% &#8211; 80 % / 80 % &#8211; 70 % / 70 &#8211; 60 % / 60 % &#8211; 0)</td>
    <td colspan="2">186 VAC ± 3% @ 100% load<br>120 VAC ± 3% @ 50% load</td>
  </tr>
  <tr>
    <td colspan="3">300 VAC ± 5 %</td>
    <td colspan="2">300 VAC ± 3%</td>
  </tr>
  <tr>
    <td colspan="3">290 VAC ± 5 %</td>
    <td colspan="2">290 VAC ± 3%</td>
  </tr>
  <tr>
    <td>Frequency Range</td>
    <td colspan="3">40Hz ~ 70 Hz</td>
    <td colspan="2">46~54 Hz or 56~64 Hz</td>
  </tr>
  <tr>
    <td>Power Factor</td>
    <td colspan="3">≧ 0.99 @ nominal voltage</td>
    <td colspan="2">≧ 0.99 @ 100%load</td>
  </tr>
  <tr>
    <td colspan="6"><strong>OUTPUT</strong></td>
  </tr>
  <tr>
    <td>Output Voltage</td>
    <td colspan="3">200/208/220/230/240 VAC</td>
    <td colspan="2">208/220/230/240 VAC</td>
  </tr>
  <tr>
    <td>AC Voltage Regulation (Batt. Mode)</td>
    <td colspan="5">± 1%</td>
  </tr>
  <tr>
    <td>Frequency Range (Synchronized Range)</td>
    <td colspan="3">47 ~ 53 Hz or 57 ~ 63 Hz</td>
    <td colspan="2">46~54 Hz or 56~64 Hz</td>
  </tr>
  <tr>
    <td>Frequency Range (Batt. Mode)</td>
    <td colspan="3">50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz</td>
    <td colspan="2">50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz</td>
  </tr>
  <tr>
    <td>Current Crest Ratio</td>
    <td colspan="5">3:1</td>
  </tr>
  <tr>
    <td>Harmonic Distortion</td>
    <td colspan="3">≦ 3 % THD (Linear Load),<br>≦ 6% THD (non-linear load)</td>
    <td colspan="2">≦ 3 % THD (Linear Load)<br>≦ 5 % THD (Non-linear Load)</td>
  </tr>
  <tr>
    <td rowspan="2">Transfer Time</td>
    <td>AC Mode to Batt. Mode</td>
    <td colspan="4">Zero</td>
  </tr>
  <tr>
    <td>Inverter to Bypass</td>
    <td colspan="3">4 ms (Typical)</td>
    <td>Zero</td>
  </tr>
  <tr>
    <td>Waveform (Batt. Mode)</td>
    <td colspan="5">Pure Sinewave</td>
  </tr>
  <tr>
    <td colspan="6"><strong>EFFICIENCY</strong></td>
  </tr>
  <tr>
    <td>AC Mode</td>
    <td>88%</td>
    <td>89%</td>
    <td>90%</td>
    <td>92%</td>
    <td>93%</td>
  </tr>
  <tr>
    <td>Battery Mode</td>
    <td>83%</td>
    <td>87%</td>
    <td>88%</td>
    <td>90%</td>
    <td>91%</td>
  </tr>
  <tr>
    <td colspan="6"><strong>BATTERY</strong></td>
  </tr>
  <tr>
    <td>Battery Type</td>
    <td>12 V / 9Ah</td>
    <td>12 V / 9Ah</td>
    <td>12 V / 9Ah</td>
    <td>12 V / 9 Ah</td>
    <td>12 V / 9 Ah</td>
  </tr>
  <tr>
    <td>Numbers</td>
    <td>2</td>
    <td>4</td>
    <td>6</td>
    <td>16</td>
    <td>16</td>
  </tr>
  <tr>
    <td>Typical Recharge Time</td>
    <td>9 hours recover to 90% capacity</td>
    <td colspan="2">4 hours recover to 90% capacity</td>
    <td colspan="2">9 hours recover to 90% capacity</td>
  </tr>
  <tr>
    <td>Charging Current (max.)</td>
    <td>1.0 A / 2.0 A (adjustable)</td>
    <td colspan="2">1.0 A</td>
    <td colspan="2">1.0 A / 2.0 A (adjustable)</td>
  </tr>
  <tr>
    <td>Charging Voltage</td>
    <td>27.4 VDC ± 1%</td>
    <td>54.7 VDC ± 1%</td>
    <td>82.1 VDC ±1%</td>
    <td>218.4 VDC ±1%</td>
    <td>218.4 VDC ±1%</td>
  </tr>